国产欧美精品一区二区三区,,gogogo免费高清在线,午夜影院 中文 无码,精品久久久噜噜噜久久久 ,日本野外强奷在线播放va,久久久久AV综合网成人,伊人无码一区二区三区,日韩精品国产二区三区
Welcome to Shenzhen Yuanxinda Electronic Instrument Co., Ltd.
深圳市源信達電子儀器有限公司
深圳市源信達電子儀器有限公司
Service Hotline
TEL:0755-85292815
Mobile:13590213125

products

Contact us

You are here:Home >> products >> Network Analyzer...

Network Analyzer

37247D Network Analyzer

Model:
37247D Network Analyzer
Product Brand:
Anritsu
Fixed Telephone:
0755-85292815
Contact Number:
13590213125 (WeChat)
Contact QQ:
2538252977
Business Scope:
Leasing, sales, recycling, maintenance

    Anritsu 37247D Network Analyzer
    The 37000D series Lightning series microwave/millimeter wave vector network analyzer integrates various high-performance test functions to meet the growing test requirements from the defense, aerospace/aerospace, broadband communications, and optoelectronic device markets. The technology and actual performance used in the Lightning series are advanced today. In addition to fast and accurate S-parameter measurement, it also supports many higher-level measurements, including: time domain, gain compression, harmonics, intermodulation, Frequency conversion device measurement, multi-port measurement, and optical/electrical and electrical/optical device measurement. Such a comprehensive measurement system can cover 20GHz, 40GHz, and 67GHz frequency bands, and the corresponding product models are 37x47D, 37x69D and 37x97D, respectively.

    For measurement requirements above 67GHz, the ME7808C broadband VNA test system based on Lightning is the solution. The award-winning ME7808C broadband VNA test system supports fast continuous scanning from 40MHz to 110GHz. Such a wide single-scan frequency coverage makes the ME7808C very suitable for on-wafer testing and device modeling applications. In addition, ME7808C can also be configured as a millimeter wave measurement system. The millimeter wave measurement system is an economical version of a broadband measurement system that can cover V, E, and W frequency bands in sections, and the extended frequency band can reach 500 GHz. The ME7808C measurement system needs to use an external frequency extension module. Many manufacturers around the world can provide such a module. For specific information, please contact Anritsu‘s local representative offices.

    In order to more effectively support the measurement of multi-port devices, the Lightning series can also test systems with 4 ports, 8 ports or 12 ports. Multi-port expansion requires external test sockets, port expansion modules, and multi-port calibration software. In addition, the multi-port expansion also supports on-wafer measurement (need to purchase a probe station separately).

    The 37300D series has all the features of the Lightning series. It is an ideal instrument for testing passive and active devices. The standard configuration includes step attenuator, internal bias seat, gain compression function and ultra-wide frequency range. Simply add a broadband test socket, two synthetic sources and the desired millimeter wave module, and any 37300D can be configured as an ME7808C millimeter wave VNA.
    ● Multi-source control and frequency offset
    ● E/O and O/E applications
    ● Gain compression application
    ● Built-in offset seat
    ● Extended power range (the source and receiver have step attenuators)
    ● Rear panel IF input (used to upgrade to millimeter wave)
    ● N×N calibration during mixer measurement
    ● Implantation/Peeling Application
    ● High-precision frequency reference
    ● 1Hz frequency resolution

    The 37200D series is an economical dual-port vector network analyzer, which is specially designed for passive device testing. It eliminates the need for devices that are only required for testing active devices. Simply add a broadband test socket, two synthetic sources and the desired millimeter wave module, and any 37200D can be configured as an economical millimeter wave VNA.
    ● Multi-source control and frequency offset
    ● E/O and O/E applications
    ● Rear panel IF input (used to upgrade to millimeter wave)
    ● N×N calibration during mixer measurement
    ● Implantation/Peeling Application
    ● High-precision frequency reference
    ● 1Hz frequency resolution

    Commonly used model 37247D 40MHz-20GHz, two-port vector network analyzer (economical passive component testing)
    37269D 40MHz-40GHz, two-port vector network analyzer (economical passive component testing)
    37297D 40MHz-65GHz, two-port vector network analyzer (economical passive component testing)
    37347D 40MHz-20GHz, two-port vector network analyzer (full-function passive/active device testing)
    37369D 40MHz-40GHz, two-port vector network analyzer (full-function passive/active device testing)
    37397D 40MHz-65GHz, two-port vector network analyzer (full-function passive/active device testing)
    ME7808C 40 MHz-110 GHz (expandable to 500 GHz) ultra-wideband and millimeter wave vector network measurement system (millimeter wave device testing)

    Main technical features
    ●High-speed data transmission and control
    With dual GPIB standard ports for data transmission and control peripherals
    ●Time domain analysis (optional)
    Through the 37000D time-domain analysis option, high-speed time-domain analysis of the device can be performed
    ● Multi-source control and enter receiver mode Through multi-source control, 37000D can easily realize the functions of test mixer and frequency multiplier. The frequency of 2 sources can be controlled separately, and the receiver can be controlled without the need of an external controller. You can specify the scan range and output power of the signal source and the scan range of the receiver. When the 37000D enters the receiver mode, the receiver is tuned by phase-locking with the internal crystal oscillator. ●Software tools and capabilities The ultimate solution with automatic testing software
    ●NxN calibration function for error correction of frequency conversion device measurement
    ●Internal control automatic calibration part Built-in software, connected to AutoCal module through the interface, to achieve fast, accurate and repeatable calibration
    ●Implant/Peel The peel function can remove the influence of the test fixture and other networks on the test results
    Implant function can be used as an analog matching circuit for optimizing amplifiers and other designs
    ●Large-capacity memory makes it easy to perform measurements with devices with multiple settings, and can quickly store and recall commonly used settings and calibrations
    ●Flexible test socket (optional) Configure 6 loops: 4 direct access receiver loops and 2 auxiliary signal source loops for testing mixers, antennas, and connection to external test sockets
    Upgradability
    According to user requirements, expand the frequency range and add new functions. Software upgrade is simple and convenient

    Calibration part
    Includes all precise components for all 12 calibrations
    Mechanical coaxial calibration parts
    3650 SMA/3.5mm calibration piece
    3650-1 SMA/3.5mm calibration piece with sliding load
    3651 GPC-7 Calibration Parts
    3651-1 GPC-7 calibration piece with sliding load
    3652 K connector calibration kit
    3652-1 K connector calibration piece with sliding load
    3653 N connector calibration kit
    3654B V connector calibration kit with sliding load
    3656 W1 (1mm) connector calibration kit/verification kit
    AutoCal? Automatic calibration module
    The built-in software connects to the AutoCal module through the interface to achieve fast, accurate and repeatable calibration
    36581NNF N(m)-N(f), 40MHz-18GHz
    36581KKF K(m)-K(f), 40MHz-20GHz
    36582KKF K(m)-K(f), 40MHz-40GHz
    Waveguide calibration parts
    3655V WR-15 Waveguide Calibration Parts
    3655V-1 WR-15 waveguide calibration kit with sliding load
    3655E WR-12 Waveguide Calibration Parts
    3655E-1 WR-12 waveguide calibration kit with sliding load
    3655W WR-10 Waveguide Calibration Parts
    3655W-1 WR-10 waveguide calibration piece with sliding load

    Verification piece
     3661 Type N
     3666 SMA/3.5mm
     3667 GPC-7
     3668 Type K
    3669B V type
    Function options
    Option 1 Cabinet mounting kit with sliding plate
    Option 1A cabinet mounting kit without sliding plate
    Option 2A time domain measurement function, which can perform high-speed time domain analysis of the device
    Option 4A external SCSI-2 hard drive compatible function
    Option 7A replaces the K-type test port with a GPC-7 connector
    Option 7N replaces K-type test port with N(m) connector
    Option 7NF replaces K-type test port with N(f) connector
    Option 7S replaces the K-type test port with a 3.5mm (m) connector
    Option 7K replaces the V-type test port with a K(m) connector
    Option 15 Flexible test device, providing direct access to 4 reference and test channels, and adding two auxiliary signal source loops for connecting amplifiers for each port
    Option 98 Z40/25 Calibration Guide
    Option 99 Advanced Calibration

    Test port cable converter
    High-precision isophase adapter, use AutoCal? auto-calibration module together with K-type, use SMA or 3.5mm connector, it will not affect the calibration accuracy
    36583S SMA type
    36583L 3.5mm type
    36583K Type K
    Test port cable
    High-performance stable phase flexible cable
    3671A50-1 K(f)-GPC-7, 63.5cm (25 inches), 1 pair
    3671A50-2 K(f)-GPC-7, 96.5cm (38 inches)
    3671S50-1 K(f)-3.5mm(m), 63.5cm(25 inches), 1 pair
    3671S50-2 K(f)-3.5mm(m), 96.5cm(38 inches)
    3671K50-1 K(f)-K(m), 63.5cm (25 inches), 1 pair
    3671K50-2 K(f)-K(m), 96.5cm (38 inches)
    3671K50-3 K(f)- K(f) and K(f)- K(m), 63.5cm (25 inches)
    3671V50-3 V(f)-V(m), 63.5cm (25 inches), 1 pair
    3671V50-3 V(f)-V(m), 96.5cm (38 inches)
    Economical semi-rigid cable
    3670A50-1 GPC-7, 30.5cm (12 inches)
    3670A50-2 GPC-7, 61cm (24 inches)
    3670N50-1 N(f)-N(m), 30.5cm (12 inches)
    3670N50-2 N(f)-N(m), 61cm (24 inches)
    3670NN50-1 N(m)-N(m), 30.5cm (12 inches)
    3670NN50-2 N(m)-N(m), 61cm (24 inches)
    3670K50-1 K(f)-K(m), 30.5cm (12 inches)
    3670K50-2 K(f)-K(m), 61cm (24 inches)
    3670KF50-1 K(f)- K(f), 30.5cm (12 inches
    3670KF50-2 K(f)-K(f), 61cm (24 inches)
    3670V50-1 V(f)-V(m), 30.5cm (12 inches)
    3670V50-2 V(f)-V(m), 61cm (24 inches)

    Precision adapter
    Coaxial
    K220B DC-40GHz, 50Ω, K(m)-K(m)
    K222B DC-40GHz, 50Ω, K(f)-K(f)
    K224B DC-40GHz, 50Ω, K(m)-K(f)
    34VK50 DC-46GHz, 50Ω, V(m)-K(m)
    34VKF50 DC-46GHz, 50Ω, V(m)-K(f)
    34VFK50 DC-46GHz, 50Ω, V(f)-K(f)
    34VV50 DC-65GHz, 50Ω, V(m)-V(m)
    34VVF50 DC-65GHz, 50Ω, V(m)-V(f)
    34VFV50 DC-65GHz, 50Ω, V(f)-K(f)
    Waveguide to Coaxial
    Provide 18GHz-65GHz various types of waveguides were converted into K-type and V-type adapters
    35WR15V 50-65GHz WR15-V(m)
    35WR15VF 50-65GHz WR15-V(f)
    35WR19K 40-50GHz WR19-K(m)
    35WR19KF 40-50GHz WR19-K(f)
    35WR19V 40-60GHz WR19-V(m)
    35WR19VF 40-60GHz WR19-V(f)
    35WR22K 33-50GHz WR22-K(m)
    35WR22KF 33-50GHz WR22-K(f)
    35WR22V 33-50GHz WR22-V(m)
    35WR22VF 33-50GHz WR22-V(f)
    35WR28K 26.5-40GHz WR28-K(m)
    35WR28KF 26.5-40GHz WR28-K(f)
    35WRD180K 18-40GHz WRD180-K(m)
    35WRD180KF 18-40GHz WRD180-K(f)
    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    *

    *

Related products

主站蜘蛛池模板: 松潘县| 南雄市| 亚洲国产欧美在线人成最新| 黑人又粗又长又大| 新沂市| 精品一区二区三区免费毛片爱| 中国www高清激情| 亚洲小视频| 亚洲天堂精品在线| 欧美A√| missav成人网| 欧美中文字幕精品人妻| 亚洲中文字| ww国产内射精品后入国产| 男公厕里同性做爰| 在线a亚洲视频播放在线观看| 无码av在线播放| 维西| 亚洲国产精品无码一线岛国 | 在线观看国产精品入口男同 | 色综合a怡红院怡红院| 久久99精品久久久久久久清纯| 亚洲国产精品羞羞| 锡林浩特市| www色色| 国产精品2区| 偷拍一女多男做爰免费视频| 麻豆安全免费网址入口| 精品免费一区二区在线| 久久天堂综合亚洲伊人hd妓女| 一本加勒比波多野结衣| www.亚洲成年人网站| 国产乱妇4p交换乱免费视频| www色色| 精品乱码一区二区| 国产老熟妇| 婷婷六月亚洲中文字幕| 亚洲国产精品无码一线岛国| 人妻一区二区三区| 国产?熟女| 日本一区精品视频|